Abstract

The intra-articular injection of a radiopharmaceutical agent (radiosynovectomy) produces a reduction of the synovial inflammatory process. The inflammed synovial membrane can be identified with magnetic resonance imaging after the intravenous administration of gadolinium (MRI-Gd). A 6-month prospective study was carried out in 10 patients with rheumatoid arthritis after radiosynovectomy of the knee. The efficacy was evaluated with clinical parameters and MRI-Gd. A progressive amelioration of synovial effusion, pain, articular range of mobility, total leucocytes count in synovial fluid and synovial membrane thickness through MRI-Gd was observed. The global efficacy was considered to be good in six patients, fair in three and bad in one. The study shows for the first time that MRI-Gd allows the evaluation of the response of the synovial membrane to radiosynovectomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call