Abstract
At present, seismic load evaluation for design of Indian buildings are carried out using Indian seismic code. In which, building Time period, Response Reduction factor and Importance factor alters design base shear majorly. Currently IS code defines Importance factor differently as “1” for general buildings and “1.5” for public buildings. This factor makes public buildings as heavier sections as it increases design base shear. However there are no evidence that, how this importance factor affects/alters/improves the seismic behavior of buildings. In this present study, four storey RC frames are designed with different importance factors. Pushover analyses are carried out to find its effects on over strength factor and response reduction factor.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.