Abstract

Little is known about the impact of treatment with drug-eluting stents (DES) on calcified coronary lesions. This analysis sought to assess the safety and efficacy of the XIENCE V everolimus-eluting stent (EES) in patients with calcified or noncalcified culprit lesions. The study population consisted of 212 patients with 247 lesions, who were treated with EES alone. Target lesions were angiographically classified as none/mild, moderate, or severe grades of calcification. The population was divided into two groups: those with at least one target lesion moderately or severely calcified (the calcified group: 68 patients with 75 calcified lesions) and those with all target lesions having mild or no calcification (the noncalcified group: 144 patients). Six-month and 2-year angiographic follow-up and clinical follow-up up to 3 years were completed. The baseline characteristics were not significantly different between both groups. When compared with the noncalcified group, the calcified group had significantly higher rates of 6-month in-stent angiographic binary restenosis (ABR, 4.3% vs. 0%, P = 0.03) and ischemia-driven target lesion revascularization (ID-TLR, 5.9% vs. 0%, P = 0.01), resulting in numerically higher major cardiac adverse events (MACE, 5.9% vs. 1.4%, P = 0.09). At 2 years, when compared with the noncalcified group, the calcified group presented higher in-stent ABR (7.4% vs. 0%, P = 0.08) and ID-TLR (7.8% vs. 1.5%, P = 0.03), resulting in numerically higher MACE (10.9% vs. 4.4%, P = 0.12). At 3 years, ID-TLR tended to be higher in the calcified group than in the noncalcified group (8.6% vs. 2.4%, P = 0.11), resulting in numerically higher MACE (12.1% vs. 4.7%, P = 0.12). The MACE rates in patients treated with EES for calcified lesions were higher than in those for noncalcified lesions, but remained lower than the results of previously reported stent studies. EES implantation in patients with calcified culprit lesions was safe and associated with favorable reduction of restenosis and repeat revascularization. © 2010 Wiley-Liss, Inc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.