Abstract

Cone-beam computed tomography (CBCT) can distort dentition, and additional imaging is often required. A plaster model to help digitize dental images has been widely used in clinical practice, but there are some inconveniences such as complexity of the process and the risk of damage. The aim of this study was to evaluate the potential for improving dentition imaging with CBCT scans using an intraoral scanner instead of a plaster model. The study used laser model-scanned images of plaster models, imaging from two intraoral scanners, and CBCT images from 20 patients aged 12-18 years. CS 3600 (Carestream Dental, Atlanta, USA) and i700 (Medit, Seoul, Korea) were used as intraoral scanners. The full arch was scanned at once or in three sections using intraoral scanners. The segmented scans were merged to obtain full-arch images. With i700, full-arch images were additionally acquired using its “smart stich” function. The virtual skull-dentition hybrid images obtained from intraoral scanners were superimposed with images obtained using a plaster cast. The difference and distance of coordinate values at each reference point were measured. The average distances from the images obtained with the plaster cast were smaller than 0.39 mm, which is the voxel size of CBCT. Scanning the complete or partial arch using CS 3600 or i700 satisfactorily complemented the CBCT when compared to the plaster model. The virtual skull-dentition hybrid image obtained from intraoral scanners will be clinically useful, especially for patients and surgeons who have difficulty in scanning the complete arch at once.

Highlights

  • The utilization of three-dimensional (3D) digital images to create a virtual treatment plan has recently gained popularity in the dental field [1–3]

  • cone-beam computed tomography (CBCT) images have limitations in providing accurate information for the following two reasons: first, CBCT images are scattered by enamel, restorations, implants, orthodontic devices, etc., resulting in streak artifacts

  • To display accurate information about the dentition in the CBCT image, it is necessary to supplement it with additional dentition imaging

Read more

Summary

Introduction

The utilization of three-dimensional (3D) digital images to create a virtual treatment plan has recently gained popularity in the dental field [1–3]. Cone-beam computed tomography (CBCT) can be used to provide 3D information on a patient’s craniomaxillofacial region. Virtual simulations can be used to plan maxillofacial surgery, and computeraided design/manufacturing technologies can be used to create dental wafers and implant surgery guides [4–7]. CBCT images have limitations in providing accurate information for the following two reasons: first, CBCT images are scattered by enamel, restorations, implants, orthodontic devices, etc., resulting in streak artifacts. The X-ray beam, which is a CBCT measurement method, does not always create perfectly uniform images [8–11]. To display accurate information about the dentition in the CBCT image, it is necessary to supplement it with additional dentition imaging.

Objectives
Methods
Results
Discussion
Conclusion