Abstract
The luminance and luminous flux of external-electrode, mercury-free, Xe flat discharge fluorescent lamp for LCD backlights and lighting equipment are equivalent to those of conventional Hg fluorescent lamps. However its efficacy is lower. In this paper, improvement of efficacy was attempted. First, the electrode width was reduced from 1.0mm to 0.5mm in order to widen the operating pressure margins. This enabled the Xe partial pressure to be increased from 1.2 kPa to 3.0 kPa, which increased efficacy 60%. Then a MgO, which has a high secondary electron emission coefficient, was coated on the dielectric layer, improving efficacy a further 10%. As a results, an efficacy of 35 lm/W with a luminance 10,100 cd/m2 were obtained with a 2.8-inch diagonal lamp.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.