Abstract

Hypoxia-inducible factor prolyl hydroxylase inhibitors (HIF-PHIs) are new therapeutic agents for anaemia in chronic kidney disease (CKD). We evaluated by meta-analysis and meta-regression the efficacy and safety of HIF-PHIs in patients with CKD-related anaemia. We selected phase 3 randomized clinical trials (RCTs) comparing HIF-PHIs and erythropoiesis-stimulating agents (ESAs) in dialysis and non-dialysis patients. Efficacy outcomes were the changes from baseline of haemoglobin, iron parameters (hepcidin, serum iron, TIBC, TSAT, ferritin) and intravenous iron dose; as safety outcomes we considered cancer, adjudicated major adverse cardiovascular events (MACE), MACE+ (MACE plus hospitalization for hearth failure or unstable angina or thromboembolic event), thrombotic events (deep vein thrombosis, pulmonary embolism), arterovenous fistula (AVF) thrombosis and death. We included 26 RCTs with 24387 patients. Random effect meta-analysis of the unstandardized mean difference between HIF-PHIs and ESAs showed a significant change in haemoglobin levels from baseline of 0.10g/dL (95% CI 0.02 to 0.17). Meta-regression analysis showed a significantly higher haemoglobin change for HIF-PHIs in younger patients and versus short-acting ESA (0.21g/dL, 95% CI 0.12 to 0.29 versus -0.01, 95% CI -0.09 to 0.07 in studies using long-acting ESA, P<.001). No significant effect on heterogeneity was found for type of HIF-PHIs. In comparison with ESAs, HIF-PHIs induced a significant decline in hepcidin and ferritin and a significant increase in serum iron and TIBC, while TSAT did not change; intravenous iron dose was lower with HIF-PHI (-3.1mg/week, 95% CI -5.6 to -0.6, P=.020). Rate ratio of cancer (0.93, 95% CI 0.76 to 1.13), MACE (1.00, 95% CI 0.94 to 1.07), MACE+ (1.01, 95% CI 0.95 to 1.06), thrombotic events (1.08, 95% CI 0.84 to 1.38), AVF thrombosis (1.02, 95% CI 0.93 to 1.13) and death (1.02, 95% CI 0.95 to 1.13) did not differ between HIF-PHIs and ESAs. HIF-PHIs at the doses selected for the comparisons are effective in correcting anaemia in comparison with ESA therapy with a significant impact on iron metabolism without notable difference among various agents. No safety signals emerge with use of HIF-PHIs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call