Abstract
N coh / N Comp and NK β / NK α intensity ratios of scattered photons by Zn in the linear region and the infinite mass thickness region are measured as functions of the pressure used for compressing the pellets with a Si(Li) detector using Am-241 and Fe-55 annular source. Besides, the effect on the experimental intensity ratio of relation between two different thicknesses of sample with applied different pressures on the sample is investigated in this study. Harmony between the linear and infinitive (critical) thickness region and the applied pressure on the sample has directly affected the experimental intensity ratios. Experimental results were not compared with various theoretical values in the literature, for present results constitute the first experimental measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Quantitative Spectroscopy and Radiative Transfer
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.