Abstract

Studies of flexible plates made of plastic have shown that less osteoporosis develops beneath them than beneath rigid metal plates. However, to date plastic plates of appropriate physical properties and biocompatibility are not available for use in humans. To determine if a similar beneficial effect could be obtained using metal plates, the effects of thick chromium cobalt plates were contrasted in experiments in dogs with the effects of thinner plates of similar design made of titanium, 6-aluminum, 4-vandium. A significant reduction in the osteoporosis was obtained by use of the more flexible plates. Following plate application a delayed, massive, transient stimulus to bone formation occurred endosteally, periosteally, and intracortically. Despite this, a substantial decrease in bone mass occurred, primarily mediated by endosteal bone resorption. Intracortical porosity played little or no role in net bone loss. The major effects subsided by six months. Recovery after plate removal was predominantly the result of endosteal new-bone formation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.