Abstract

Results of linear-bifurcation buckling and nonlinear analyses of the Space Shuttle superlightweight external liquid-oxygen tank are presented for an important prelaunch loading condition. These results show the effects of actual, measured welding-induced initial geometric imperfections on an important response mode for thin-walled shellsthataresubjectedtocombinedmechanicalandthermalloads.Thistypeofinitialgeometricimperfectionmay be encountered in the design of other liquid-fuel launch vehicles. Results are presented that show that the liquidoxygen tank will buckle in the barrel section, but at load levels nearly four times the magnitude of the operational load level, and will exhibit stable postbuckling behavior. The actual measured imperfections are located in this sectionofthetank. Resultsofimperfection sensitivity analysesarepresented thatshowthat thelargestdegradation in the apparent membrane stiffnesses of the liquid-oxygen tank barrel section is caused by an imperfection shape that is in the form of the linear-bifurcation buckling mode with a relatively small amplitude. These results also show that the effect of the relatively large-amplitude measured imperfection is benign.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.