Abstract
The effects of a heat barrier, located in the ceiling wall of an enclosure, on conjugate conduction/natural convection are investigated numerically. The vertical walls of the enclosure are differentially heated and the horizontal walls are adiabatic. Heatline technique is used to visualize heat transport. The variations of average Nusselt number, dimensionless heat transfer rate through the ceiling wall, and dimensionless overall heat transfer rate are studied. Calculations are performed for different Rayleigh numbers (103 ≤ Ra ≤ 106), thermal conductivity ratios (1 ≤ K ≤ 100), dimensionless locations of the heat barrier (0 < X h < 1),and two dimensionless ceiling wall thicknesses (D = 0.05 and D = 0.20). For high thermal conductivity ratio (K = 100), the heat barrier considerably reduces the dimensionless overall heat transfer rate. The effect of the heat barrier on dimensionless heat transfer rate through the enclosure increases as the Rayleigh number decreases. For low Rayleigh number (i.e., Ra = 103), a location exists in the ceiling wall for which the dimensionless overall heat transfer rate is minimum.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.