Abstract

Effects of ultra high speed (UHS) floor burnishing upon air quality in health care facilities were evaluated. A 2,000-rpm burnisher can disseminate high-velocity (190 km/hr) dust and microbial particles. A UHS burnisher used with either inadequate or no air restraint produced significant increases (P less than 0.05) in the levels of airborne dust particles and microorganisms. A UHS burnisher equipped with an air restraint assembly specifically designed for use in health care facilities produced no significant increase (P greater than 0.05) in the levels of airborne dust particles or microorganisms when compared to ambient air levels. The types and distribution of airborne microorganisms isolated from microbial air samples were not unusual nor were they directly influenced by the floor burnishing processes. Furthermore, the UHS floor burnishing process produced a significant reduction (P less than 0.05) in microbial floor contaminants (96%). When the use of UHS floor burnishing is contemplated for productivity improvement and esthetic enhancement, the possible adverse effects on air quality should also be considered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.