Abstract

This paper reports on an investigation into the influence of an expansive admixture (EA) and fly ash (FA) on the axial compressive behaviour of concrete-filled glass-fibre-reinforced polymer (GFRP) tube columns. The effect of EA and FA on the compressive strength and restrained expansion ratio was studied for two concrete strength grades, and optimised mixtures of expansive FA concrete were selected. It was found that the desired concrete strength and maximum expansion was obtained with 12% substitution of EA and 10% substitution of FA. For this study, 12 concrete-filled GFRP tube columns of circular cross-section were designed and fabricated considering parameters including the GFRP tube thickness, EA content, FA dosage and concrete strength. Their axial compressive behaviour was investigated through their failure modes, load-carrying capacity, ultimate stress and stress–strain curves. The results showed that increases in the thickness of the GFRP tube and EA content can enhance the axial compressive strength of concrete-filled GFRP tube columns. The theoretical ultimate load results showed good agreement with the experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.