Abstract

Effects of tube inclination angles on nucleate pool boiling heat transfer of water at atmospheric pressure have been investigated experimentally. Experiments were performed for seven angles (0, 15, 30, 45, 60, 75, and 90°) with two tubes (12.7 and 19.1 mm in diameter) of 540 mm in length. Through the study, it can be concluded that tube inclination gives much change on nucleate pool boiling heat transfer. When the tube is near the horizontal and the vertical positions, the maximum and minimum of heat transfer coefficients are expected, respectively. The decrease in bubble slug formation on the tube surface and easy liquid access to the surface are thought to be the causes for the enhanced heat transfer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.