Abstract

BackgroundThe meniscus is critical for the normal functioning of the knee joint. The specific aim of this study was to validate an in vitro culture model of meniscus explants for testing the impact of culture conditions on meniscus biomechanical properties. We hypothesized that culturing menisci in the presence of intermediate and high concentration of serum would have a positive effect on the compressive stiffness of the meniscus. MethodsUnconstrained microindentation testing was performed on porcine meniscus explants cultured with varying concentrations 1%, 5%, or 10% of fetal bovine serum media. Meniscus explants that were not cultured were used as a control. These tests quantified the Young's Modulus of the listed groups of cultured and uncultured explant tissues. FindingsThe Young's modulus for 10% cultured explants were significantly higher compared to the control, 1%, and 5% cultured meniscus explants. There was no statistical significance when the Young's modulus between control, 1%, and 5% cultured explants were compared. InterpretationThese results suggest that low concentrations of serum do not impart an anabolic effect on meniscus tissue explant biomechanical properties.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.