Abstract
Abstract The recently developed post-IR IRSL SAR protocol is promising to isolate more stable IRSL signals of feldspars. However, the high temperature thermal treatments used will inevitably induce thermally transferred post-IR IRSL295 (TT-post-IR IRSL295) signal, which would contribute to the measured post-IR IRSL295 signal of the test dose and may lead to inaccurate sensitivity correction. In this study, the effects of TT-post-IR IRSL295 signal in the post-IR IRSL295 SAR protocol are investigated using medium polyminerals from a loess section at Caoxian, northwestern Loess Plateau in China. The sensitivity changes of the IRSL50 and the post-IR IRSL295 signals are different from natural cycle to regenerative cycles, which can be attributed to the interference of the TT-post-IR IRSL295 signal. Such difference is dependent on the test dose and the post-IR IR stimulation time. The TT-post-IR IRSL295 signal is also shown to affect the post-IR IRSL295 Do and De values and to cause overestimation of the fading rates. Our study therefore highlights the need of serious consideration on the effects of TT-post-IR IRSL signal when the post-IR IRSL SAR protocol is employed for dating.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.