Abstract

Thermoacoustic Oscillations (TAOs) is a commonly experienced phenomenon in helium cryogenics and in most cases, is an undesirable effect. During LCLS-II prototype Cryomodule (pCM) testing, TAOs were observed in both the Cryogenics Distribution System and in the LCLS-II Cryomodule JT and Cooldown Valves. The TAOs manifested themselves through the usual effect of added heat load to the cryogenic system and ice formation on the oscillating device. However, during cavity testing, the TAOs were also found to significantly contribute to microphonics detuning of the SRF cavities. Systematic studies were carried out and it was discovered that the TAOs could be “turned-off” or substantially decreased by operating at subcritical pressures on the LHe supply. Lastly, various TAO dampening/mitigation techniques were employed to allow operations at supercritical pressure with greatly reduced static heat load and microphonics levels.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.