Abstract
To examine the effects of firefighting personal protective ensemble (PPE) and self-contained breathing apparatus (SCBA) on exercise performance, 12 males completed two randomly ordered, graded exercise treadmill tests (GXTPPE and GXTPT). Maximal oxygen consumption (VO2max) during GXTPPE was 17.3% lower than the GXTPT in regular exercise clothing (43.0 ± 5.7 vs. 52.4 ± 8.5 ml/kg per min, respectively). The lower VO2max during the PPE condition was significantly related (r = 0.81, p < 0.05) to attenuated peak ventilation (142.8 ± 18.0 vs. 167.1 ± 15.6 l/min), which was attributed to a significant reduction in tidal volume (2.6 ± 10.4 vs. 3.2 ± 0.4 l). Breathing frequency at peak exercise was unchanged (55 ± 7 vs. 53 ± 7 breaths/min). The results of this investigation demonstrate that PPE and the SCBA have a negative impact on VO2max. These factors must be considered when evaluating aerobic demands of fire suppression work and the fitness levels of firefighters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.