Abstract

The cylindrical capacitive sensor (CCS) is superior to conventional probe-type sensors in measuring the radial error motion of a rotor accurately since the CCS is immune to geometric errors of the rotor. However, due to the extended axial length of the CCS, the obliquity (or the axial tilt) of the rotor may cause unnecessary measurement error. This paper presents the effects of rotor obliquity on the performance of the CCS. The existing analytical model for the CCS has been extended to incorporate the axial tilt of the rotor, which leads to a new mathematical model for the CCS that can describe the complete three-dimensional motion of the rotor. Based on the new mathematical model, a nonlinear analysis is performed to derive the analytical solution of the measured rotor displacement with the CCS. As a result, it has been revealed how the rotor obliquity causes measurement errors in both eccentricity and phase angle. The analytical results are compared and verified with simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.