Abstract
AbstractThe objective of this work is to present a novel geometrical configuration for microbubble generators (MBGs) to improve dissolved‐oxygen levels in water. Among various methodologies from the literature, Orifice and Venturi tubes have been considered as baseline cases. Experimental data from the literature are used to verify a computational fluid dynamics (CFD) case developed for a better understanding of the dynamics of MBGs. As a result, the validated CFD setup has been implemented on a modified Venturi‐type generator, where air is injected coaxially with respect to the tube axis, whereas a helicoid wall at variable pitch angle is used. Results show a reduction in the mean bubble diameter distribution from the baseline Venturi tubes, particularly, at low‐speed inlet velocities. This is of interest, especially to decrease the energy requirement for most common water aeration systems.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.