Abstract

The reset current (Ireset), voltage (Vreset), and resistance of the low resistance state, as functions of the compliance current (CC), were investigated in a Pt/NiO/Pt structure that showed unipolar resistance switching. Interestingly, the Ireset and the Vreset measured at low CCs were found to be widely distributed. In order to explain the behavior of the reset parameters for the singly-connected conducting filament (CF) structure, a simple model of CFs was employed whose width variation follows the Gaussian distribution. The wide distribution of the reset parameters can be attributed to the fluctuation in the number and/or the width of the CFs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call