Abstract

Air-staged combustion which moves parts of the jet of tertiary air to the top of Primary combustion zone for reducing the generation of NOx in a 300 MW pulverized-coal boiler with Swirl Burner. The primary purpose of this work is to investigate the effect of moving parts of the jet of tertiary air and changing the ratio of tertiary air on the distribution of temperature, the efficiency of combustion and the emission of NOx. When the ratio of upper tertiary air is increasing, the concentration of NOx is decreasing, but the carbon content in fly ash is increasing and it will affect the efficiency of combustion. Comprehensive comparison of all projects, when the ratio of upper tertiary air is 70%, the carbon content in fly ash is 3.31% and the emission concentration of NOx in the export of air preheater can decrease to 767mg/Nm3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.