Abstract
To evaluate the effects of delay and spectral alteration of speech feedback (SF) on the speaking rate and voice pitch in adult users of hearing aids (HAs) and cochlear implants (CIs). Repeated-measure, completely crossed, 2-factor design. Spectral alterations were implemented by replacing SF with noise that was filtered into 1-, 2-, or 4-frequency bands and speech-modulated in real time. Delays varied from 25 to 200 milliseconds. Seven HA users with severe to profound hearing loss and 6 CI users were randomly recruited by public advertising. All were postlingually deafened adults with intelligible speech. The average speaking rate significantly decreased and rate variability significantly increased with increase in SF delay for both groups. Spectral alterations of SF reduced the effect on speaking rate in the HA group but not in the CI group. Spectral alterations did not significantly affect rate variability in the HA group but did so in the CI group. Average voice pitch increased significantly with increase in SF delay and with spectral alterations of SF in the HA group. No significant effects on average pitch of CI users were noted. The 2 groups were affected differently by the delay and spectral alterations of SF. The differences possibly reflect greater spectral resolution ability in the case of CI users and greater audibility of bone-conducted SF (particularly in the low-frequency region) among the HA users.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Archives of Otolaryngology–Head & Neck Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.