Abstract
A cost effective single-chamber microbial fuel cell (MFC) integrated with adsorption system was tested under different operating temperatures to observe pH profiles, organics, solids, nutrients, color and turbidity removal and power density generation. The optimum operating temperature range was found to be ∼25–35°C with majority of the removals achieved at ∼35°C. Maximum power density recorded was 74±6mW/m3 with coulombic efficiency (CE) of 10.65±0.5% when operated at 35°C. Present studies had successfully demonstrated the effectiveness of a hybrid system in removing various types of pollutants in POME at optimum temperature and able to fulfill the stringent effluent discharge limit. Chemical oxygen demand (COD), total solids (TS) and turbidity removals increase linearly with temperatures with removal efficiency of 0.5889%C−1, 1.0754%C−1 and 0.7761%C−1, respectively. The temperature coefficient (Q10) is found to be 1.06, 1.45 and 1.09, respectively. Besides, MFC-adsorption hybrid system had demonstrated superior stability over a wide range of operating temperatures in terms of COD removal as compared to the non-integrated MFC system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.