Abstract

The effect of temperature/humidity treatment conditions on the interfacial adhesion energy between an electroless-plated Ni film and a polyimide substrate was evaluated by using a 180° peel test. The measured peel strength values decrease from 506.1 ±18.6 to 231.9 ±33.3 J/m2 due to the temperature/humidity treatment at 85 °C/85% relative humidity for 1000 h. X-ray photoelectron spectroscopy analysis of the peeled surfaces indicates that peeling occurs cohesively inside of the polyimide; this is related to both the decrease in the interfacial adhesion energy and the polyimide degradation when small quantities of the remaining alkali ions react with the polyimide's functional groups during the temperature/humidity treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.