Abstract

In this study, local measurement and computational fluid dynamics (CFD) were employed to evaluate the thermal comfort in a residential environment where desiccant cooling is performed in an outdoor air condition, which is the typical summer weather in Korea. The desiccant cooling system in the present study has been developed for multi-room control with a hybrid air distribution, whereby mixing and displacement ventilation occur simultaneously. Due to this distribution of air flow, the thermal comfort was changed, and the thermal comfort indicators conflicted. The evaluation indicators included the ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) comfort zone, predicted mean vote (PMV), and effective draft temperature (EDT). The dry-bulb temperature displayed a distribution of 26.2–26.8 °C in the cooling spaces, i.e., living room, kitchen, and dining room. When determined based on the standard ASHRAE comfort zone, the space where desiccant cooling takes place entered the comfort zone for summer. Due to the influence of solar radiation, the globe temperature was more than 2 °C higher than the dry-bulb temperature at the window. A difference of up to 6% in humidity was observed locally in the cooling space. In the dining room located along the outlet of the desiccant cooling device, the PMV entered the comfort zone, but was slightly above 1 in the rest of the space. Conversely, as for the EDT, its value was lower than −1.7 in the dining room, but was included in the comfort zone in the rest of the space. By adjusting the discharge angle upward, the PMV and EDT were expected to be more uniform in the cooling space. In particular, the optimum discharge angle obtained was 40° upward from the discharge surface.

Highlights

  • In Korea, the demand for heating varies greatly depending on the season, but the heat-to-electricity ratio of cogeneration cannot be adjusted according to the fluctuations of demand [1]

  • The effective draft temperature (EDT) index is commonly used for the evaluation of thermal comfort in air-conditioning spaces with ventilation, such as desiccant cooling systems [18]

  • In the desiccant cooling space, there was no noticeable difference in the thermal comfort of each space as observed in the ASHRAE comfort zone

Read more

Summary

Introduction

In Korea, the demand for heating varies greatly depending on the season, but the heat-to-electricity ratio of cogeneration cannot be adjusted according to the fluctuations of demand [1]. If the thermal comfort is evaluated using this index, the comparison would be difficult because both conventional air conditioners and desiccant cooling are included in the comfort area [8,13]. The EDT index is commonly used for the evaluation of thermal comfort in air-conditioning spaces with ventilation, such as desiccant cooling systems [18]. Studies that analyzed the effect of discharge angle on flow distribution, energy efficiency and thermal comfort by CFD have been published [21,22,23,24]. For floor standing type air conditioners, the optimum discharge angle considering energy consumption and thermal comfort was calculated to be 30◦ upward [21].

Hybrid Desiccant Cooling System and Air-Conditioned Space
Hybrid
PMV Measurements
Flow Simulaton
Temperature and Humidity
Air Flow and Thermal Comfort
Effects of Air Supply Angle on Thermal Environment