Abstract
Abstract A parametric study is conducted to predict effects of structural parameters on operating characteristic of a solenoid used for gas injector. To describe operation of the solenoid injector, two simulation models are established including an electrical model and a mechanical model. The solenoid injector is also modeled and simulated in Maxwell and Simplorer based on the specifications of a real solenoid injector. Structural parameters, such as spring stiffness, mass of the plunger, and number of turns, are changed to investigate their effects on the operating characteristics of the solenoid injector, including the current, electromagnetic force, and displacement of the plunger. The simulation results show that changes in spring stiffness, mass of the plunger, and number of turns have significant effects on the electromagnetic force and displacement of the plunger in the solenoid injector. In particular, the increase in plunger mass results in fluctuating plunger displacement, which can affect the quality of injection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.