Two faults related to the Pine Mountain overthrust sheet near Buchanan County, Virginia, were investigated to determine their effect on ground control and to develop recognition criteria for prediction. Both faults are right lateral, strike-slip faults overprinted simultaneously with thrust faulting. Offsets of the coal seam due to thrust faulting average 6 ft with severe roof conditions (20 ft high roof falls) occurring through an average 30 ft wide zone of disturbance. Recognition criteria include characteristic overthrusting, coalbed swag, bedding plane slippage, and fault gouge. Ground control strategies include mine designs that minimize fault exposure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.