Ligand-gated ion channel kinetics were studied in mammalian transfected cells encoding adult mouse muscle acetylcholine (ACh) receptors. We measured macroscopic and single-channel currents using the outside-out and cell-attached patch-clamp configurations. Cultured cells were exposed to moderate intensity inhomogeneous static magnetic fields up to 180 mT and measurements were performed for temperatures ranging from 5 to 50 °C. We found no significant changes in ACh-elicited macroscopic or single-channel currents. We observed the expected dependence in current decay constants with temperature, but negligible magnetic field influence on the channel's kinetics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.