Abstract
Ligand-gated ion channel kinetics were studied in mammalian transfected cells encoding adult mouse muscle acetylcholine (ACh) receptors. We measured macroscopic and single-channel currents using the outside-out and cell-attached patch-clamp configurations. Cultured cells were exposed to moderate intensity inhomogeneous static magnetic fields up to 180 mT and measurements were performed for temperatures ranging from 5 to 50 °C. We found no significant changes in ACh-elicited macroscopic or single-channel currents. We observed the expected dependence in current decay constants with temperature, but negligible magnetic field influence on the channel's kinetics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.