Abstract

The effects of soil type of Shanghai and electrode potential from cathodic protection point on near-neutral pH stress corrosion cracking (SCC) behavior of pipeline steel X60 has been investigated for structural integrity assessment. The SCC behavior was evaluated through slow strain rate tests (SSRT) at various electrode potentials in three solutions containing different typical soils. Results showed that the SCC susceptibility generally increased with decreasing electrode potential in all the three environments, with quick increase happening in the range from-1500 to-700mV(SCE). It is suggested that hydrogen induced cracking should dominate the SCC at low potentials. In cathodic potential range, the rank of the SCC susceptibility for soil type was Near-city soil > Cyan-purple soil > Cyan-yellow soil. In anodic potential range, SCC susceptibility curves mixed each other in the three solutions.