Abstract
Quenching experiments were conducted to investigate the effect of deposition of SiC and graphene oxide (GO) nanoparticles on heat transfer during rapid cooling in vertical tubes. Temperature histories during quenching were measured for each test section to confirm the effect of the nanoparticle-coated layer on quenching performance. Boiling curves for each test were obtained by using the inverse heat transfer method. Quenching performance was enhanced ∼20% to 31% for nanoparticle-coated tubes compared to the bare tube. Scanning electron microscope images of the inner surfaces of the tubes following the experiments were acquired, and the contact angles were measured to observe the effect of surface structures and wettability on quenching performance. In the case of tubes coated with GO nanoparticles for 900 s, quenching performance and critical heat flux (CHF) were enhanced although the contact angle increased. To confirm the surface effect on the enhanced quenching performance and CHF of GO nanoparticle–coated tubes, FC-72 refrigerant was used as the working fluid of the quenching experiment to reduce the wettability effect on the heat transfer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Nuclear Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.