Abstract

It has been well known that a scatter in axial bolt forces of pipe flange connections tightened by the torque control method is substantial. In practice, pipe flange connections with the larger nominal diameter tightened by the torque control method have been used, frequently. So, in an optimum design of pipe flange connections with gaskets, it is necessary to understand the characteristics of the pipe flange connections with larger nominal diameter under internal pressure and the contact gasket stress distributions due to the scatter of the axial bolt forces in the connections tightened by the torque control method. In this paper, the leakage tests were performed in the actual larger pipe flange connections with 20” nominal diameter using helium gas. Then, the effects of the scatter in the axial bolt forces tightened by the torque control method on the gas leakage were also examined. By using the calculated contact stress distributions and the results of the leakage tests, the sealing performance was evaluated.