Abstract

Thermal transient water tests were performed using a simplified hot plenum model of a pool-type LMFBR to examine the fundamental characteristics of thermal stratification during reactor trips. These tests were divided into two series to clarify the effects of (1) Reynolds number and (2) Richardson number on the behavior of thermal stratification. The results of the first series indicated that the characteristics of thermal stratification were independent of Reynolds number in the range of Re > 10 4. It was concluded from the results of the second series that the rising speed of the thermal interface and the temperature gradient at the interface varied proportionally with Ri −1 2 and Ri 1 2 , respectively. In addition, large scale internal waves, called internal standing waves, were observed under the condition of Re > 10 4 and 1 < Ri < 5.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.