Abstract

In order to investigate the effects of probe support on the stall characteristics of micro compressors, an experiment was carried out on a large-scale low-speed research compressor according to the principle of geometric similarity. A cylindrical probe support intruding to 50% blade span was mounted at 50% chord upstream from the rotor blade leading edge. The static pressure rise characteristic of the compressor is measured, with and without the probe support respectively. The dynamic compressor behavior from pre-stall to full stall was also measured. The results indicate that the stability margin of the compressor is lowered after installing the probe support. The stall inception is aroused by modal wave disturbances. The disturbances developed into two stall cells smoothly before installing the probe support, while the disturbances first developed into a single stall cell then splitting into two stall cells after installing the probe support. The presence of probe support lowers the initial intensity of the rotating stall of the compressor, while it doesn’t alter the intensity of the rotation stall after the compressor enters into full stall.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.