Abstract

Heparin-induced thrombocytopenia (HIT) is a hypercoagulable state caused by a transient antibody to heparin-bound platelet factor 4 (PF4). Treatment involves discontinuing heparin and administering a nonheparin anticoagulant. Procedures requiring heparin, such as cardiopulmonary bypass, are preferably delayed until the offending antibody is no longer detectable. For patients with a high-titer anti-PF4-heparin antibody and who require exposure to heparin, therapeutic plasma exchange (TPE) has been used to remove the antibody. Recent work indicates that a functional assay for detecting platelet-activating antibodies in HIT patients, the serotonin release assay (SRA), is preferable to ELISAs for anti-PF4-heparin antibodies for following the effectiveness of plasma exchange. Two cases of acute heparin-induced thrombocytopenia managed with plasma exchange before emergent cardiac surgery were evaluated with SRAs using a range of heparin concentrations that included those used in cardiopulmonary bypass. We observed that a single round of plasma exchange led to greater reduction in platelet reactivity at heparin concentrations between 1 and 3 U/mL than at lower concentrations, consistent with the impression that heparin-PF4-antibody complexes form optimally within a limited heparin concentration range. The findings suggest there may be a range of heparin concentration in which cardiac surgery may be safely performed in HIT patients, and that a single TPE in an emergent setting may lower antibody concentration sufficiently to lower platelet reactivity in the presence of heparin.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call