Abstract
AbstractLow‐temperature atmospheric pressure plasmas applied to the surface of an aqueous solution have been shown to be efficient bactericides for bacteria suspended in the solution, if the solution is sufficiently acidic. Especially of interest is the finding that there is a critical pH value of about 4.7 for the bactericidal effects, below which the bacteria are efficiently inactivated and above which the bacteria are hardly affected by the plasma application. It has been also found that the presence of superoxide anion radicals O• in the solution is essential for bacterial inactivation by the plasma application. Therefore, the critical pH value may arise from the pKa of the equilibrium reaction between O• and hydroperoxy radicals HOO•, which is known to be approximately 4.8. The present experiments, where plasmas are not directly applied to bacterium surfaces and it has been confirmed that neither UV light nor heat from the plasma is the cause of bacterial inactivation, suggest the importance of highly reactive species generated in the solution via plasma–liquid interaction for the bactericidal effects. magnified image
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.