Abstract
Abstract The relationship between the passivation period of Si-containing steel and oxygen concentrations was investigated by conducting the oxidizing experiments employing four different oxygen concentrations on a simultaneous thermal analyzer (STA) at a heating temperature of 1260°C. The results show that the duration of passivation period increased with the increasing oxygen concentration. Moreover, the passivation period occurred at the oxygen concentrations ranging from 2.0 vol.% to 3.0 vol.%, whereas no visible passivation period was observed at the oxygen concentrations ≤1.5 vol.%. In addition, the oxidation mass gain versus time followed a linear relationship before the passivation period, which lasted for about 20 min when the mixed binary atmosphere was introduced into the sample chamber right from the beginning of the heating process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.