Abstract

To evaluate the effect of orthoptic treatment on the AC/A (A, accommodation; C, convergence) and CA/C ratios in subjects with convergence insufficiency (CI). The change in AC/A and CA/C ratios after a 12-week period of home-based orthoptic treatment was examined in 10 subjects (mean age, 25.4+/-4.1 years [SD]). Both the AC/A and CA/C ratios were measured by using gradient response methods. For the AC/A ratio, the gradient phoria method was used, and for the CA/C ratio the prism-induced change in accommodation was measured with a refractometer. No change in the AC/A and CA/C ratios (P>0.05) were found after orthoptic treatment. However, improvements were found (P<0.05) in the fast and slow vergence mechanisms. Despite improvements in the fast and slow vergence mechanisms no change was found in the AC/A and CA/C ratios after orthoptic treatment in CI subjects. This finding is unexpected in light of the present understanding of CI, and an alternative theory is proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.