Abstract
Interest in the size distribution of particles emitted from biomass cookstoves stems from the hypothesis that exposure to ultrafine particles is more detrimental to human health than exposure to accumulation mode or other size regimes. Previous studies have reported that gasifier cookstoves emit smaller particles than other cookstove designs under steady operating conditions. In the present study, the number size distribution of particles emitted from a forced-air gasifier cookstove was measured at 1 Hz as the stove transitioned between several steady and transient operating modes. During normal operation, when the stove functioned as a top-lit updraft gasifier, the distribution was bimodal, with peaks at 10 nm and 40 nm, when a pot of water was on the stove. The distribution became unimodal with a peak at 10 nm when the pot was removed. Once the fuel bed had completely gasified and the secondary flame extinguished, the concentration of particles increased and the peak in number concentration shifted to a...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.