Abstract

Ingress of air from neighboring apartments is an important source of fine particulate matter (PM2.5) in residential multi-story buildings. It affects the measurement and estimation of particle deposition rate and penetration factor. A blower-door method to measure the particle deposition rate and penetration factor has previously been found to be more precise than the traditional decay-rebound method as it reduces variability of PM2.5 ingress from outside. CONTAM is a multi-zone indoor air quality and ventilation analysis computer program to aid the prediction of indoor air quality. It was used in this study to model the indoor PM2.5 concentrations in an apartment under varying PM2.5 emission from neighboring apartments and window opening and closing regimes. The variation of indoor PM2.5 concentration was also modeled for different days to account for typical outdoor variations. The calibrated CONTAM model aimed to simulate environments found during measurement of particle penetration factor, thus identifying the source of error in the estimates. Results show that during simulated measurement of particle penetration factors using the blower-door method for three-hour periods under a constant 4 Pa pressure difference, the indoor PM2.5 concentration increases significantly due to PM2.5 generated from adjacent apartments, having the potential to cause an error of more than 20% in the estimated value of particle penetration factor. The error tends to be lower if the measuring time is extended. Simulated measurement of the decay-rebound method showed that more PM2.5 can penetrate inside if the PM2.5 was generated from apartments below under naturally variable weather conditions. A multiple blower-door fan can be used to reduce the effects of neighboring emission and increase the precision of the penetration estimates.

Highlights

  • Poor indoor air quality can affect human health

  • Cross-infection contributed to the spread of the virus, which was found in rooms where residents did not suffer from the disease [8], for single-sided naturally ventilated buildings in Hong Kong

  • It is likely to be caused by increased propagation of variable outdoor conditions under natural ventilation

Read more

Summary

Introduction

Poor indoor air quality can affect human health. As multi-apartment dwellings become an increasing part of urban life, pollution within them assumes greater importance.In contemporary cities residents generally spend 80–90% of their time indoors [1,2]. Apart from the indoor sources, the penetration of outdoor airborne contaminants through ventilation and infiltration is one of the most important factors in controlling air quality indoors [3]. In multistory residential buildings in larger cities, airborne contaminants may arise from the outside environment, but through inter-zone transmission [4]. This provides another important pathway for indoor air pollutants and health impacts [5]. Wang et al [11] used a Computational Fluid Dynamics (CFD) model to investigate pollutant transmission inside and outside a multistory building with singlesided, buoyancy-driven ventilation, and dependence on window type. Mu et al [12,13]

Methods
Results
Conclusion