Abstract

Earlier studies have shown that nasalization affects the radiated spectrum by modifying the vocal tract transfer function in a complex manner. Here we study this phenomenon by measuring sine-sweep response of 3-D models of the vowels /u, a, ᴂ, i/, derived from volumetric MR imaging, coupled by means of tubes of different lengths and diameters to a 3-D model of a nasal tract. The coupling introduced a dip into the vocal tract transfer function. The dip frequency was close to the main resonance of the nasal tract, a result in agreement with the Fujimura & Lindqvist in vivo sweep tone measurements [Fujimura & Lindqvist, 1972]. With increasing size of the coupling tube the depth of the dip increased and the first formant peak either changed in frequency or was split by the dip. Only marginal effects were observed of the paranasal sinuses. For certain coupling tube sizes, the spectrum balance was changed, boosting the formant peaks in the 2 - 4 kHz range. A velopharyngeal opening introduces a dip in the transfer function at the main resonance of the nasal tract. Its depth increases with the area of the opening and its frequency rises in some vowels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.