Abstract

Based on the test results of the La solubility in iron-saturated liquid zinc, the galvanized coatings with the unsaturated (0.006 wt%), saturated (0.012 wt%), and supersaturated (0.2 wt%) lanthanum (La) additions were prepared on mild steel surface in this study. The microstructure and corrosion resistance of coated specimens were studied by optical microscope (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), weight loss tests and electrochemical methods. These results illustrated that La partially dissolved in Zn. On the other hand, La reacted with Zn to form LaZn13 and promoted the dendritic growth of coating. The weight loss of La-containing galvanized coatings decreased by 5–25% gradually due to the inhibition of cathodic reaction. The results of SKP indicated the number of micro cells decreased with the La addition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.