Abstract

BackgroundThe aim of this prospective and complete cross-over study was to evaluate the effects of isoflurane, remifentanil and dexmedetomidine on EEG parameters derived from the Narcotrend® Monitor before and after nociceptive stimulation at different isoflurane MAC (minimal alveolar concentration) multiples. Seven adult European Domestic Short Hair cats were used. Each cat went through 3 experimental treatments. Group I received isoflurane, group IR received isoflurane and a constant rate infusion (CRI) of remifentanil (18 μg/kg/h IV), and group ID received isoflurane and a CRI of dexmedetomidine (3 μg/kg/h IV). The isoflurane MAC in each group was determined via supramaximal electrical stimulation. The EEG parameters were derived by a Narcotrend Monitor at specific time points before and after nociceptive stimulation at 0.75, 1.0 and 1.5 MAC.The depth of anaesthesia was also assessed by a clinical score.ResultsThe mean MAC sparing effects in group IR and group ID were 9.8 and 55.2%, respectively. The best correlation of EEG and MAC multiples was found for the Narcotrend Index (NI) in group I (r = − 0.67). The NI was also able to differentiate between 0.75 MAC and 1.5 MAC in group IR. Spectral edge frequency had a lower correlation with MAC multiples in group I (r = − 0.62) but was able to differentiate between 0.75 MAC and 1.5 MAC in groups I and IR, and between 1.0 MAC and 1.5 MAC in group IR. Narcotrend Index, SEF 95 and MF increased significantly after nociceptive stimulation at 1.0 MAC in group I, and SEF 95 increased significantly at 0.75 MAC in group ID. The clinical score correlated closer than any of the EEG parameters with MAC in all groups, with highest correlation values in group I (r = − 0.89). Noxious stimulation led to a significant increase of the clinical score at 0.75 MAC and 1.0 MAC in group I.ConclusionsThe EEG parameters derived from the Narcotrend Monitor show correlation to isoflurane MAC multiples in cats, but the anaesthetic protocol and especially the addition of dexmedetomidine have great influence on the reliability. The Narcotrend Monitor can be used as an additional tool to assess anesthetic depth in cats.

Highlights

  • IntroductionThe aim of this prospective and complete cross-over study was to evaluate the effects of isoflurane, remifentanil and dexmedetomidine on EEG parameters derived from the Narcotrend® Monitor before and after nociceptive stimulation at different isoflurane Minimum alveolar concentration (MAC) (minimal alveolar concentration) multiples

  • The aim of this prospective and complete cross-over study was to evaluate the effects of isoflurane, remifentanil and dexmedetomidine on EEG parameters derived from the Narcotrend® Monitor before and after nociceptive stimulation at different isoflurane Minimum alveolar concentration (MAC) multiples

  • The EEG parameters derived from the Narcotrend Monitor show correlation to isoflurane MAC multiples in cats, but the anaesthetic protocol and especially the addition of dexmedetomidine have great influence on the reliability

Read more

Summary

Introduction

The aim of this prospective and complete cross-over study was to evaluate the effects of isoflurane, remifentanil and dexmedetomidine on EEG parameters derived from the Narcotrend® Monitor before and after nociceptive stimulation at different isoflurane MAC (minimal alveolar concentration) multiples. Because the interpretation of raw EEG data is difficult without special knowledge and time-consuming [4], more application-oriented solutions such as the BIS, CSM and Narcotrend Monitor [5,6,7,8,9] have been invented They use special algorithms for processing the raw EEG data, thereby allowing real-time interpretation and providing the anaesthesiologist with clinically useful information. The Narcotrend Monitor’s algorithms, which are based on a visual classification of human sleep EEG, spectral parameters and the detection of burst suppression lines [14], are able to identify specific sleep EEG patterns which are processed and result in the displayed dimensionless Narcotrend Index (NI), ranging from 0 (electrical silence) to 100 (awake). This index corresponds to six displayed EEG stages, ranging from A to F, with 15 substages

Objectives
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.