Abstract

Intraabdominally insufflated carbon dioxide (CO2) during laparoscopy may have a specific effect on splanchnic circulation that may be unrelated to the effects of increased intraabdominal pressure alone. Therefore, the influences of insufflation with CO2 versus air on splanchnic circulation were compared. Pigs were chronically instrumented for continuous recording of mesenteric artery, portal venous, inferior vena cava, and pulmonary arterial blood flow and portal venous pressure. After induction of anesthesia, CO2 or air was insufflated in 14 and 10 pigs, respectively. With the pigs in the supine position, intraabdominal pressure was increased in steps of 4 mmHg up to 24 mmHg by graded gas insufflation. During air insufflation, mesenteric artery vascular resistance was unchanged, whereas mesenteric arterial blood flow decreased with increasing intraabdominal pressure. Shortly after CO2 insufflation to an intraabdominal pressure of 4 mmHg, mean arterial pressure, mesenteric arterial blood flow, and mesenteric arterial vascular resistance were increased by 21%, 12% and 9%, respectively. Subsequently, with the onset of CO2 resorption in the third minute, mean arterial pressure declined to baseline values and mesenteric arterial vascular resistance declined to 85% of baseline values, whereas mesenteric arterial blood flow continued to increase to a maximum of 24% higher than baseline values. At steady-state conditions during CO2 insufflation, mesenteric arterial blood flow was increased up to an intraabdominal pressure 16 mmHg but decreased at higher intraabdominal pressures. In contrast to air insufflation, intraabdominal insufflation of CO2 resulted in a moderate splanchnic hyperemia at an intraabdominal pressure < or = 12 mmHg. At higher intraabdominal pressure values, pressure-induced changes became more important than the type of gas used.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call