Abstract

The effects of increasing heart rate by six different methods on cardiac function were investigated in 17 open-chest anesthetized dogs. Heart rate was increased approximately 30% by (1) right interganglionic nerve stimulation, (2) atrial pacing, (3) ventricular pacing, (4) atrioventricular sequential pacing, (5) right stellate ganglion stimulation, and (6) isoproterenol administration. During heart rate increases induced by atrial pacing left ventricular intramyocardial pressure, coronary blood flow, oxygen delivery per unit of myocardial oxygen consumption, and myocardial efficiency were unchanged. Ventricular pacing reduced left ventricular cavity and septal intramyocardial pressure, while circumflex coronary flow increased, resulting in reduced oxygen delivery relative to myocardial oxygen consumption. Similarly, atrioventricular sequential pacing increased circumflex coronary artery flow and myocardial oxygen consumption, and decreased septal intramyocardial pressure and oxygen delivery per unit of myocardial oxygen consumption. Right stellate ganglion stimulation and isoproterenol increased left anterior descending and circumflex coronary artery blood flow, intramyocardial pressure, and myocardial oxygen consumption. Estimated myocardial efficiency (left ventricle) was decreased by ventricular pacing and isoproterenol, and was unchanged by atrial pacing and right interganglionic nerve stimulation. Increases in heart rate induced by right interganglionic nerve stimulation did not alter myocardial oxygen consumption, or the index of cardiac efficiency. It is concluded that augmentation of heart rate by either ventricular or atrioventricular pacing impairs myocardial function so that there is a decrease of left ventricular efficiency and isoproterenol augments chronotropism and myocardial force relative to cardiac external work so there is a reduction in cardiac efficiency. In contrast, atrial pacing or right interganglionic nerve stimulation augments chronotropism such that myocardial oxygen consumption and efficiency are unchanged.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.