Abstract

X80 pipeline steel specimens were treated by electrochemical hydrogen charging under various current density and charging time. The polarization resistance and corrosion rate of X80 steel were analyzed in Yingtan simulated soil solution under the different hydrogen charging conditions. The results showed that hydrogen accelerated anodic dissolution and enhanced corrosion sensitivity. With hydrogen in the steel, the charge transfer resistance and polarization resistance decreased, double electric layer capacitor and corrosion current increased. The effects were enhanced with the increase of hydrogen charging time and current density.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.