Abstract

To achieve practical treatment of photo-processing waste (PW) using our previously proposed sulfur-oxidizing bacteria (SOB)/granular activated carbon (GAC) sludge system, this paper elucidates why 3- to 5-X dilution of PW was required. That is, a series of experiments were carried out to show the effects of high salinity and constituent organic compounds in PW, respectively. Both an inorganic salts system and calcination PW system showed that SOB completely oxidizes S 2O 3 2–-S to SO 4 2–-S even at 12.3 or 13.6% salinity, respectively; hence the dilution requirement is not attributable to high salinity. In experiments employing SOB and SOB/GAC systems to investigate the effects of 23 constituent compounds in PW, compounds were classified into Groups I, II, IIIa, and IIIb. Even with 10 g/l GAC, the nine compounds in Group IIIb still exhibited a toxic effect on SOB activity at 1- and 3-X dilutions; thus it is these compounds that are responsible for requiring dilution of PW. Accordingly, a reduction in their use within the photo-developing and fix-stabilizing industry, and/or use of >10 g/l GAC, are new considerations for establishing a more practical PW treatment process.