Abstract

Although the isopropanol precipitation test is a commonly used and sensitive test for detecting unstable hemoglobins, false-positive reactions are frequently observed. In this study, the storage temperature of the test samples, type of stored sample amount of fetal hemoglobin (Hb F) in the sample, and presence of potassium cyanide (KCN) in the hemolysate preparation all affected the accuracy of the test. The addition of 2% KCN to samples before testing eliminated or greatly reduced false-positive reactions. Hb F levels greater than 4% caused false-positive results. When specimens with Hb F levels less than 4% were stored at 4C and as whole blood, they showed no false-positive reaction for as long as two weeks. However, duplicate specimens stored as whole blood but unrefrigerated and those stored as hemolysates showed false-positive reactions after three days.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.