Abstract

Potentiodynamic polarization analysis was performed on heat-treated (quenched, normalized, or annealed) and epoxy-coated rebar steel samples in 3.5% NaCl solutions. Two types of epoxy coatings including a commercially available (Araldite LY 1556 with Aradur 2964 as curing agent, brushed) and FibreGlast with Resin 2000 epoxy coating (sprayed) using manufacturer’s recommendations were utilized in this study. Optical microscopy, hardness testing, and potentiodynamic polarization were carried out to study microstructure, hardness, and corrosion resistance of the bare and epoxy-coated rebar steel samples. Bare, as-received, rebar samples exhibited the highest corrosion rate of 11.93 μA/cm2 followed by quenched bare sample with 4.2 μA/cm2. Annealed and normalized rebar samples showed corrosion rates of 2.8 and 2.6 μA/cm2, respectively. All epoxy-coated samples exhibited lower corrosion rates compared to their uncoated counterparts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.