Abstract
By using the method of finite element, a numerical simulation of heat transfer of the compressed air in a closed square cavity with high temperature heater. Analyze the effects of heat transfer performance, temperature and flow field in closed cavity with different arrangement of heater. Provide a basis for optimizing heater arranged location. The transfer area of heater is the same. And the structure form of the heater includes quadrilateral centered, cross centered and piecewise evenly arranged. Heating efficiency is highest when the heater quadrilateral centered and when heater cross centered, the temperature of the cavity is best in the horizontal direction
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.