Abstract

We investigated the effects of head rotation on the cross-sectional area of the right internal jugular vein and its relative position to the carotid artery. Eighty-eight subjects were divided into infants and children groups. The cross-sectional area of the right internal jugular vein and the degree of the carotid artery overlap were measured at 0 degrees (neutral), 40 degrees and 80 degrees of head rotation. The cross-sectional area of the right internal jugular vein was significantly larger at 40 degrees and 80 degrees head rotation compared with the neutral position in both infants and children (p < 0.001). As the head was rotated, the percentage overlap of the carotid artery increased significantly (p < 0.001). We suggest that 40 degrees head rotation appears to be optimal for right internal jugular vein cannulation in paediatric patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.